HID ProxPro with Keypad 5355

HID ProxPro with Keypad 5355 - Access control system

HID Reader, HID ProxPro with Keypad 5355, hid reader, access control system
  • Accepts 5 to16 volts, meeting most voltage requirements.
  • Available with Wiegand or Clock-and-data interface.
  • Allows easy upgrade from magstripe to a proximity reader; no rewiring or pulling of new cable required.
  • Offers high reliability, consistent read-range and low power consumption in an easy-to-install package.
  • Mounts directly onto metal with no change in read range performance.
  • Provides multicolor LED, compatibility with all standard access control systems and internal or host control of LED and beeper..
  • Rated Hazardous Locations Class I, Div. 2, Groups A,B,C,D.

The HID MiniProx Hazardous Location 5365 provides the same features and dimensions as the MiniProx reader, with an incorporated junction box rated for use in hazardous locations. The junction box is attached to an appropriate surface location utilizing four holes.

Typical Maximum Read Range :

  • HID ProxCard II Card - up to 5.5" (14 cm)
  • HID ISOProx II card - up to 5" (12.5 cm)
  • HID ProxKey II keyfob - up to 2" (5 cm)
  • HID ProxCard Plus card - up to 2" (5 cm)
  • HID SmartProx II card - up to 5" (12.5 cm)

*Depending on local installation conditions.

  • Dimensions : 6.0" x 1.7" x 1.0" (15.2 x 4.3 x 2.54 cm)
  • Power Supply
    • Standard MiniProx : 5.1-16 VDC
    • Haz. Loc. MiniProx : 5.1-16 VDC
    • Linear power supplies are recommended
  • Maximum Current Requirements
    • Average : 100 mA (12 VDC)
    • Peak : 120 mA (24 VDC)
  • Operating Temperature : -22º to 150º F (-30º to 65º C)
  • Operating Humidity : 0-95% relative humidity non-condensing
  • Weight : With terminal strip 3.5 oz. (99 gm) With pigtail 3.8 oz. (108 gm) Haz. Loc. MiniProx: 3.8 oz. (108 gm)
  • Current Requirements : Average: 40 mA (5 VDC); 50 mA (12 VDC) Peak: 60 mA (5 VDC); 120 mA (12 VDC)
  • Transmit frequency : 125 kHz
  • Excite frequency : 125 kHz
  • Cable distance
    • Wiegand interface: 500 feet (150 m)
    • Clock-and-data interface: 50 feet (15 m)
    • Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent.
    • Additional conductors may be required for LED or beeper control
  • Certifications
    • Canada/UL 294 Listed: Access Control System Units
    • Canada/UL 1604 Listed (with Haz. Loc. junction box only):
    • Hazardous Locations Class I, Div. 2, Groups A,B,C,D.
    • FCC Certification, United States
    • Canada Certification
    • CE Mark, Europe
    • UK Type Approval
    • Germany Type Approval
    • Australia C-Tick Mark
    • New Zealand EMC