HID Prox80 5405

HID Prox80 5405 - Access control system

HID Reader, Prox80® 5405, access control system

HID Prox80 5405 is an 80 mm (3.15") square reader designed to mount directly to European and Asian size single-gang electrical back boxes.

With a three-piece, weatherproof potted enclosure and long pigtail (2.7 m / 9 ft) design, the HID Prox80 5405 is easily installed and provides up to 14 cm (5.5") of read range.

HID Prox80 5405 is used in biometric access control system, biometric attendance system.

Key Features :
  • Unique mounting plate accommodates vertical and horizontal mounting hole patterns (60 mm) and Asian (52 mm) hole spacing.
  • The long pigtail (2.7 m or 9 ft) simplifies installation by providing easy cable terminations, and increases reliability by reducing the number of cable joins.
  • Multilingual installation manual supports field personnel in the proper installation of the reader.
  • Available in a grey or white Classic Series cover design with a Wiegand or Clock-and-Data interface.
  • Provides high reliability, consistent read range and low power consumption.
  • Features include multicolor LED and internal control or host control of the LED and beeper.
  • Mounts directly on metal with minimal impact on the read range performance.
  • Can be used with all HID proximity cards and all bit formats.

Typical Maximum Read Range :

  • ProxCard® II card - up to 5.5" (14 cm)
  • ISOProx® II card - up to 5" (12.5 cm)
  • DuoProx® II card - up to 5" (12.5 cm)
  • ProxKey® II keyfob - up to 2" (5 cm)
  • MicroProx® Tag - up to 2.5" (6.2 cm)
  • ProxCard® Plus card - up to 1.5" (3.7 cm)
  • Smart ISO/DuoProx® cards - up to 2.5" (6.2 cm)
  • Proximity & MIFARE® card - up to 5" (12.5 cm)

*Depending on local installation conditions.

  • Dimensions : 3.15" x 3.15" x 0.80" (8.0 x 8.0 x 2.0 cm). Screw slots provided for 52-60mm hole spacing
  • Power Supply
    • 5-16 VDC
    • Linear power supplies are recommended
  • Current Requirements
    • Average : 30 mA (5 VDC); 20 mA (12 VDC)
    • Peak : 110 mA (5 VDC); 115 mA (12 VDC)
  • Operating Temperature : -22º to 150º F (-30º to 65º C)
  • Operating Humidity : 0-95% relative humidity non-condensing
  • Weight : 2.2 oz. (63 gm)
  • Cable distance
    • Wiegand interface: 500 feet (150 m)
    • Clock-and-data interface: 50 feet (15 m)
    • Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent.
    • Additional conductors may be required for LED or beeper control
  • Certifications
    • Canada/UL 294 Listed : Access Control System Units
    • EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety)
    • Canada/UL 294 Listed
    • Canada Certification
    • CE Mark
    • Australia C-Tick, New Zealand
    • Fifteen EU Countries under the R&TTE Directive (EN 300 330 - SRD, and ETS 300 683 - EMC)