HID ThinLine II 5395

HID ThinLine II 5395- Access control system

HID Reader, ThinLine II 5395,Access control system

Providing performance and reliability, HID's attractive, unobtrusive HID ThinLine II 5395 proximity card reader is housed in a two-piece, weatherproof secure potted enclosure.

  • The size of most standard U.S. switch plates..
  • Available with Wiegand or Clock-and-Data interface..
  • Base part numbers: 5395 (Wiegand), 5398 (Clock-and-Data)..
  • Potted reader suitable for indoor or outdoor use.
  • 18" (45 cm) wire pigtail standard; consult factory for 9' (2.7 m) pigtail available by special order.
Key Features :
  • TwoEasily installed and maintained with the use of replaceable covers.
  • Available with a Wiegand or Clock-and-Data interface.
  • Provides high reliability, consistent read range and low power consumption.
  • Features include multicolor LED and internal control or host control of the LED and beeper.
  • Mounts directly on metal with minimal impact on the read range performance. Optional kit enables mounting behind glass.
  • Aesthetic design available in two cover designs and four colors to match any décor.
  • Includes multilingual installation manual.

Typical Maximum Read Range :

  • HID ProxCard II Card - up to 5.5" (14 cm)
  • HID ISOProx II Card - up to 5" (12.7 cm)
  • HID DuoProx II Card - up to 5" (12.7 cm)
  • HID Smart ISO/DuoProx Cards - up to 5" (12.7 cm)
  • HID Proximity & MIFARE Card - up to 5" (12.7 cm)
  • HID ProxCard Plus Card - up to 1.5" (3.8 cm)
  • HID ProxKey II Keyfob - up to 2" (5.1 cm)
  • HID Microprox Tag - up to 3" (7.6 cm)

*Depending on local installation conditions.

  • Dimensions : 4.70" x 3.00" x 0.68" (11.9 x 7.6 x 1.7 cm)
  • Power Supply
    • 5-16 VDC
    • Linear power supplies are recommended
  • Operating Temperature : -22º to 150º F (-30º to 65º C)
  • Operating Humidity : 0-95% relative humidity non-condensing
  • Weight : 3.3 oz. (94 gm)
  • Cable distance
    • Wiegand interface: 500 feet (150 m)
    • Clock-and-data interface: 50 feet (15 m)
    • Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent.
    • Additional conductors may be required for LED or beeper control
  • Certifications
    • Canada/UL 294 Listed
    • EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety)
    • Fifteen EU Countries under the R&TTE Directive (EN300 330 - SRD, and ETS 300 683 - EMC)
    • FCC Certification, United States
    • Canada Certification
    • CE Mark
    • Taiwan, China
    • Australia C-Tick, New Zealand