The HID VertX Products provide a complete and fully featured hardware/firmware intrastructure for biometric access control software host systems.
The HID VertX V300 Output control Interface conects 12 latching Form-C relays, which can connect up to 12 devices controllable by simple contact closures, such as logic inputs for process equipment, HVAC and elevator control panels, CCTV Switchers, etc. Loads exceeding 2 A @ 30 VDC should be controlled via interposing relays.
The HID VertX V300 features on-board flash memory, allowing program updates to be downloaded via the network. The HID VertX V300 connects to the HID V1000 through a high speed RS-485 network.
The HID VertX V1000 communicates with the system host via industry standard TCP/IP protocol over 10/100 Mbps Ethernet or the Internet. This architecture minimizes the impact on corporate LANs, by using only one TCP/IP address for every 32 Interfaces, and by handling low-level transactions on the RS-485 network.
Key Benefits :Dimensions: | 5.8"W x 4.825"H x 1.275" D (147.32 mm x 122.55 mm x 32.38 mm) |
Weight: | 13.6 oz (0.38 kg) |
Power Supply Requirements: | 60 mA @ 9-18 VDC (with no readers connected) Recommended: Supervised linear power supply with battery backup, input surge protection, and AC fail and battery low contact outputs. Seperate supervised, DC supply battery back-up recommended for relay activated devices. |
Cable Distance: | |
RS-485: | 4000 feet (1220 m) to host, using Belden 3105A, 22AWG twisted pair, shielded 100? cable |
Output Cirbuits: | 500 feet (150 m), 2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C (18AWG) |