HID ProxPro with Keypad 5355

HID ProxPro with Keypad 5355 - Access control system

HID Reader, HID ProxPro with Keypad 5355, hid reader, access control system
  • Accepts 5 to16 volts, meeting most voltage requirements.
  • Available with Wiegand or Clock-and-data interface.
  • Allows easy upgrade from magstripe to a proximity reader; no rewiring or pulling of new cable required.
  • Offers high reliability, consistent read-range and low power consumption in an easy-to-install package.
  • Mounts directly onto metal with no change in read range performance.
  • Provides multicolor LED, compatibility with all standard access control systems and internal or host control of LED and beeper..
  • Rated Hazardous Locations Class I, Div. 2, Groups A,B,C,D.

The HID MiniProx Hazardous Location 5365 provides the same features and dimensions as the MiniProx reader, with an incorporated junction box rated for use in hazardous locations. The junction box is attached to an appropriate surface location utilizing four holes.

Typical Maximum Read Range :

  • HID ProxCard II Card - up to 5.5" (14 cm)
  • HID ISOProx II card - up to 5" (12.5 cm)
  • HID ProxKey II keyfob - up to 2" (5 cm)
  • HID ProxCard Plus card - up to 2" (5 cm)
  • HID SmartProx II card - up to 5" (12.5 cm)

*Depending on local installation conditions.

  • Dimensions : 6.0" x 1.7" x 1.0" (15.2 x 4.3 x 2.54 cm)
  • Power Supply
    • Standard MiniProx : 5.1-16 VDC
    • Haz. Loc. MiniProx : 5.1-16 VDC
    • Linear power supplies are recommended
  • Maximum Current Requirements
    • Average : 100 mA (12 VDC)
    • Peak : 120 mA (24 VDC)
  • Operating Temperature : -22º to 150º F (-30º to 65º C)
  • Operating Humidity : 0-95% relative humidity non-condensing
  • Weight : With terminal strip 3.5 oz. (99 gm) With pigtail 3.8 oz. (108 gm) Haz. Loc. MiniProx: 3.8 oz. (108 gm)
  • Current Requirements : Average: 40 mA (5 VDC); 50 mA (12 VDC) Peak: 60 mA (5 VDC); 120 mA (12 VDC)
  • Transmit frequency : 125 kHz
  • Excite frequency : 125 kHz
  • Cable distance
    • Wiegand interface: 500 feet (150 m)
    • Clock-and-data interface: 50 feet (15 m)
    • Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent.
    • Additional conductors may be required for LED or beeper control
  • Certifications
    • Canada/UL 294 Listed: Access Control System Units
    • Canada/UL 1604 Listed (with Haz. Loc. junction box only):
    • Hazardous Locations Class I, Div. 2, Groups A,B,C,D.
    • FCC Certification, United States
    • Canada Certification
    • CE Mark, Europe
    • UK Type Approval
    • Germany Type Approval
    • Australia C-Tick Mark
    • New Zealand EMC

Frequently Asked Questions

Q1. What is the HID MiniProx Hazardous Location 5365?

The HID MiniProx Hazardous Location 5365 provides the same proximity reading features as the standard MiniProx reader but includes an incorporated junction box rated for hazardous locations. It is UL 1604 Class I & II, Division 2, Groups A, B, C, D listed — making it safe for use in environments with flammable gases or vapors.

Q2. What environments is the HID MiniProx Hazardous Location 5365 approved for?

The HID MiniProx Hazardous Location 5365 is listed under UL 1604 for Hazardous Locations Class I, Division 2, Groups A, B, C, and D — covering environments where flammable gases, vapors, liquids, combustible dusts, or ignitable fibres may be present, such as chemical plants, refineries, and grain storage facilities.

Q3. What is the read range of the HID MiniProx Hazardous Location 5365?

The HID MiniProx Hazardous Location 5365 provides read ranges of up to 5.5" (14 cm) for HID ProxCard II, up to 5" (12.5 cm) for ISOProx II and SmartProx II, and up to 2" (5 cm) for ProxKey II and ProxCard Plus. Actual ranges may vary by installation conditions.

Q4. What interface and power options does the MiniProx Hazardous Location 5365 support?

The MiniProx Hazardous Location 5365 supports Wiegand (up to 500 ft) or Clock-and-Data (up to 50 ft) interfaces, operates on 5.1–16 VDC with 100 mA average and 120 mA peak current at 12 VDC, and transmits at 125 kHz.

Q5. What global certifications does the HID MiniProx Hazardous Location 5365 carry?

The HID MiniProx Hazardous Location 5365 carries UL 294 and UL 1604 (with hazardous junction box), FCC (USA), Canada, CE Mark (Europe), UK and Germany type approvals, and Australia C-Tick certification, enabling compliant deployment across major global markets.